ReliabilitySafetyCapacity

Solis-(80-110)K-5G

400V: 80K;   480V: 100K-HV;   540V: 110K-BHV

超级赛车全天人工计划 80-110kW 5G three phase series string inverter adopt 9/10 MPPT desigh to provide a more flexible configuration scheme with a smaller environmental impact rateand higher generation efficiency. Max. 13A per string, 150% DC overloading capability,Remote & local intelligent IV scan function.

80-110kW 5G Three Phase Inverter

Leading Features

  • Over 98.7% Max. effciency
  • DC input reverse alarm
  • Intelligent redundant fan-cooling
  • Fuse free design to avoid fire hazard
  • Leakage current repression technology
  • Volt-watt work mode integrated
  • Optional anti-PID function integrated
  • Wide voltage range and low startup voltage
  • 9/10 MPPT design with precise MPPT algorithm
  • THDi<3%, low harmonic distortion against grid
  • Perfect commercial site monitoring solution
  • Anti-resonance, supporting over 6MW parallelled in one transformer
  • Strings intelligent monitoring, Smart I-V Curve Diagnosis supported
  • Type II surge arrester for both DC and AC, type I surge arrestor optional
  • Integrated DC switches, AC switch optional

技术规格

Input DC

  • Max. input voltage:
    1100V
  • Rated voltage:
    600V
  • Start-up voltage:
    195V
  • MPPT voltage range:
    180-1000V
  • Max. input current:
    9*26A
  • Max. short circuit current:
    9*40A
  • MPPT number:
    9
  • Max. input strings number:
    18

Output AC

  • Rated output power:
    80kW
  • Max. apparent output power:
    88kVA
  • Max. output power:
    88kW
  • Rated grid voltage:
    3/N/PE, 220/380V, 230/400V
  • Rated grid frequency:
    50/60Hz
  • Rated grid output current:
    121.6A
  • Max. output current:
    133.7A
  • Power Factor:
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi:
    <3%

Efficiency

  • Max.efficiency:
    98.7%
  • EU efficiency:
    98.3%

Protection

  • DC reverse-polarity protection:
    Yes
  • Short circuit protection:
    Yes
  • Output over current protection:
    Yes
  • Surge protection:
    DC Type II / AC Type II (AC Type I optional)
  • Grid monitoring:
    Yes
  • Anti-Islanding protection:
    Yes
  • Temperature protection:
    Yes
  • Strings monitoring:
    Yes
  • I/V Curve scanning:
    Yes
  • Anti-PID function:
    Optional
  • Integrated AFCI (DC arc-fault circuit protection):
    Optional
  • Integrated DC switch:
    Yes
  • Integrated AC switch:
    Optional

General Data

  • Dimensions (W*H*D):
    1050*567*314.5 mm (with AC switch)
  • Weight:
    82kg
  • Topology:
    Transformerless
  • Self consumption:
    <2W (night)
  • Operating ambient temperature range:
    -25 ~ +60°C
  • Relative humidity:
    0~100%
  • Ingress protection:
    IP66
  • Cooling concept:
    Intelligent redundant fan-cooling
  • Max.operation altitude:
    4000m
  • Grid connection standard:
    VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, RD 1699, UNE 206006, UNE 206007-1, IEC 61727, DEWA
  • Safty/EMC standard:
    IEC 62109-1/-2, IEC 62116, EN 61000-6-2/-4

Features

  • DC connection:
    MC4 connector
  • AC connection:
    OT terminal (max. 185 mm²)
  • Display:
    LCD,2×20 Z.
  • Communication:
    RS485, Optional: Wi-Fi, GPRS, Ethernet, PLC
Sales Enquiries: sales@bnnsco.com
Copyright@2019 Ginlong Technologies All rights reserved