超级赛车全天人工计划

50-60kW Three Phase Inverter

Leading Features

  • Over 97% Max. effciency
  • Intelligent redundant fan-cooling
  • Wide voltage range and low startup voltage
  • THDi<3%, low harmonic distortion against grid
  • Perfect commercial site monitoring solution
  • 4 MPPT input, each rated current is 28.5A, compatible with high power module
  • Anti-resonance, supporting over 6MW parallelled in one transformer

Installation video

Installation video

Technical Specifications

Input DC

  • Recommended max. PV powerr:
    60kW
  • Max. input voltage:
    1100V
  • Rated voltage:
    600V
  • Start-up voltage:
    200V
  • MPPT voltage range:
    200-1000V
  • Max. input current:
    4*28.5A
  • Max. short circuit current:
    4*44.5A
  • MPPT number:
    4
  • Max. input strings number:
    12

Output AC

  • Rated output power:
    50kW
  • Max. apparent output power:
    55kVA
  • Max. output power:
    55kW
  • Rated grid voltage:
    3/N/PE, 220/380V, 230/400V
  • Rated grid frequency:
    50/60Hz
  • Rated grid output current:
    72.2A/76A
  • Max. output current:
    83.3A
  • Power Factor:
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi:
    <3%

Efficiency

  • Max.efficiency:
    98.8%
  • EU efficiency:
    98.4%

Protection

  • DC reverse-polarity protection:
    Yes
  • Short circuit protection:
    Yes
  • Output over current protection:
    Yes
  • Surge protection:
    Yes
  • Grid monitoring:
    Yes
  • Anti-Islanding protection:
    Yes
  • Temperature protection:
    Yes
  • Strings monitoring:
    Yes
  • Anti-PID function:
    Optional
  • Integrated DC switch:
    Optional

General Data

  • Dimensions (W*H*D):
    630*700*357 mm
  • Weight:
    63kg
  • Topology:
    Transformerless
  • Self consumption:
    <1W(Night)
  • Operating ambient temperature range:
    -25~60℃
  • Relative humidity:
    0~100%
  • Ingress protection:
    Ip66
  • Cooling concept:
    Intelligent redundant fan-cooling
  • Max.operation altitude:
    4000m
  • Grid connection standard:
    VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, RD 1699, UNE 206006, UNE 206007-1, IEC 61727, DEWA
  • Safty/EMC standard:
    IEC 62109-1/-2, IEC 62116, EN 61000-6-2/-4

Features

  • DC connection:
    MC4 connector
  • AC connection:
    OT terminal
  • Display:
    LCD,2×20 Z.
  • Communication:
    RS485, Optional: Wi-Fi, GPRS

Case Study

Sales Enquiries: sales@bnnsco.com
Copyright@2019 Ginlong Technologies All rights reserved